Disclaimer: Universal Aqua is an independent, multi-brand service and repair provider. We are not an authorized service partner, dealer, or affiliate of Kent, Aquaguard, Livpure, Pureit, or any other water purifier manufacturers. All brand names, trademarks, and logos displayed on this website remain the property of their respective owners and are used strictly for identification and compatibility purposes only.
RO Services in Your City | Universal Aqua
Professional RO Repair, Maintenance & Installation Services in Your City
Looking for reliable RO servicing, repair or installation services in your city? Universal Aqua provides professional RO maintenance and repair solutions for residential and commercial customers. Our services are designed to maintain consistent performance, address technical issues and help extend the operational life of your RO system.
Whether you need routine maintenance, troubleshooting, spare part replacement, a new system installation or an Annual Maintenance Contract (AMC), our service solutions are tailored to your system's model and requirements.
We provide service support for leading brands, including Eureka Forbes Aquaguard, Kent, Livpure, Pureit, Aquafresh, Aquagrand and other RO brands.
Our Services Include: Click on the service Tab You Want to know about
RO Brands We Serve: Click on the brand you want to know about
Our technicians are trained to handle all major domestic and commercial Reverse Osmosis (RO) models. Universal Aqua provides maintenance, repair and installation assistance for various RO system brands and models.
We offer service support for:
PUREIT RO SERVICE & REPAIR
nATURAL AQUA RO SERVICE & rEPAIR
aNY OTHER RO SERVICE & REPAIR
RO Services Offered by Universal Aqua :-Â Comprehensive RO Services & Transparent Pricing Structure
Universal Aqua offers comprehensive RO servicing solutions to help customers maintain the performance, functionality and reliability of their RO systems. From routine maintenance and technical troubleshooting to new installations and Annual Maintenance Contracts (AMC), we provide service solutions for different brands, models and system configurations.
Our services are designed to address common operational issues, identify worn-out components, improve system functionality and help prevent unexpected breakdowns. Whether your system requires periodic maintenance, component replacement or complete installation, our service approach focuses on identifying the actual requirement before recommending the appropriate solution.
We provide service assistance for Eureka Forbes Aquaguard, Kent, Livpure, Pureit, Aquafresh, Aquagrand and other compatible RO brands.
Regular RO servicing is essential for maintaining the filtration performance, water flow and overall operational condition of the system. During continuous operation, filters gradually accumulate suspended particles, carbon components lose their adsorption capacity and membranes may experience scaling or reduced filtration efficiency. Other components, such as valves, pumps, connectors and tubing, may also develop wear over time.
Universal Aqua provides detailed regular maintenance services that focus on inspecting important components, identifying performance-related issues and determining whether cleaning, adjustment or replacement is required.
Â
Our Regular RO Service Includes:
Designed as a preventive health checkup for functional RO units to maintain water taste, hygiene, and steady output flow. Recommended every 3 to 6 months.
-
Complete 10-Point System Inspection: Testing raw input water pressure, checking electrical connections, inspecting tubing joints, and verifying auto shut-off functionality.
-
Pre-Filter & Sediment Cleaning: Opening the external pre-filter bowl, flushing out trapped mud, rust, and coarse silt, and cleaning or replacing the spun cartridge as needed.
-
TDS Level Calibration & Testing: Measuring both input water TDS and output drinking water TDS using a calibrated digital TDS meter, then adjusting the TDS controller to maintain balanced mineral levels.
-
Storage Tank Cleaning & Sanitization: Draining residual water from the internal storage tank and sanitizing the interior walls to eliminate slime, biofilm, and odor buildup.
-
Flow Rate & Reject Ratio Check: Measuring the ratio of clean water to wastewater to ensure the RO membrane is operating efficiently without excessive water wastage.
Â
Benefits of Regular RO Service:
-
Helps maintain consistent filtration performance.
-
Supports proper water flow and storage tank operation.
-
Helps identify clogged filters and deteriorating components.
-
Reduces the risk of unexpected technical breakdowns.
-
Helps identify leakage and pressure-related issues.
-
Supports the operating life of pumps, membranes and other components.
-
Helps prevent unnecessary water wastage caused by faulty valves.
-
Provides an opportunity to identify maintenance requirements before they become major problems.
Regular RO Service — ₹300 + Spare Parts (if required)
RO repair service is required when the system develops a technical fault, stops operating correctly or shows signs of reduced performance. Problems may originate from filtration components, pumps, electrical connections, pressure-control mechanisms, automatic valves or water-carrying fittings.
Universal Aqua provides troubleshooting and repair assistance to identify the actual cause of operational problems and recommend suitable corrective measures. Instead of replacing components without diagnosis, our service approach focuses on examining the affected section and determining whether repair, adjustment or replacement is necessary.
Â
Our RO Repair Service Includes:
Dedicated fault-finding and corrective repair for RO systems experiencing breakdowns, performance drops, or physical leaks.
-
Root-Cause Technical Diagnostics: Systematic testing of individual components—including the SMPS power adapter, booster pump pressure, solenoid valve (SV), float switch, and UV choke—to pinpoint the exact cause of failure rather than relying on guesswork.
-
Low Flow & Clogging Resolution: Identifying whether slow output is caused by a choked sediment/carbon filter, an exhausted RO membrane, or a blocked flow restrictor (FR).
-
Leakage & Pressure Sealing: Replacing worn-out O-rings, cracked filter bowls, damaged push-fit elbow connectors, and brittle RO tubing to stop internal and external water leaks.
-
Electrical & Pump Restoration: Repairing or replacing malfunctioning booster pump heads, burnt SMPS units, faulty high/low-pressure switches, and non-functioning UV lamps.
-
Post-Repair Quality & Pressure Verification: Running a complete operational cycle after repair to confirm leak-free performance, proper auto shut-off, and safe output TDS levels.
Â
Benefits of Professional RO Repair:
-
Helps identify the actual source of technical problems.
-
Restores normal operating functions wherever repair is feasible.
-
Helps resolve water leakage and abnormal drainage issues.
-
Addresses pump, pressure and water-flow problems.
-
Helps prevent additional damage caused by faulty components.
-
Reduces unnecessary component replacement through proper diagnosis.
-
Supports reliable operation after corrective work.
RO Repair Service — ₹300 + Spare Parts (if required)
Proper installation is important for ensuring suitable water connections, secure mounting, correct electrical arrangements and reliable system operation. Incorrect installation may result in leakage, restricted water flow, poor drainage arrangements, electrical issues or difficulties during future maintenance.
Universal Aqua provides professional RO installation assistance for new systems and compatible replacement units. Our installation process focuses on selecting a suitable location, making the necessary connections and checking the system's basic operation before completing the service.
Â
Our RO Installtion Service Includes:
Professional setup and relocation support for newly purchased, unboxed, or shifted wall-mounted and under-sink RO systems.
-
Secure Wall Mounting & Alignment: Precision drilling and heavy-duty bracket mounting to ensure the unit sits level and supports the full weight of a filled storage tank without vibration.
-
Inlet Water Supply Integration: Connecting the diverter valve safely to your existing kitchen tap or dedicated cold-water supply line with proper thread sealing to prevent seepage.
-
Reject Drain Line Routing: Neat, secure routing of the wastewater outlet tube to the kitchen sink or drain point without kinks or backpressure.
-
Initial System Flushing & Air Bleeding: Flushing out food-grade preservatives from brand-new filters and membranes before filling the storage tank for first-time consumption.
-
Safe Uninstallation (for Relocation): Closing the inlet valve, draining internal water, disconnecting tubing without damaging fittings, and packing loose accessories securely for transport. (Note: Extra tubing, diverter valves, or wall brackets beyond standard box contents are billed separately if needed).
Â
Benefits of Professional RO Installation:
-
Helps ensure correct inlet, outlet and drainage connections.
-
Reduces the risk of leakage caused by improper fitting.
-
Supports suitable system positioning and stable mounting.
-
Helps ensure compatible electrical connections.
-
Supports proper functioning of the pump and automatic controls.
-
Makes future maintenance and component replacement more convenient.
-
Helps identify installation-related problems before regular usage.
RO Installation & Uninstallation Service — ₹500 + Installation Accessories (if required)
An Annual Maintenance Contract (AMC) is a planned maintenance arrangement for customers who want organised service assistance throughout an agreed contract period.
Instead of arranging individual maintenance visits whenever a problem develops, an AMC provides a structured approach to routine inspections and servicing, according to the selected plan.
Universal Aqua offers AMC options based on the brand, model, existing condition and maintenance requirements of the RO system.
AMC plans are suitable for residential and commercial customers who prefer scheduled maintenance and a more organised approach to system care.
Â
Our RO AMC Service May Includes:
A cost-effective, year-round protection plan engineered to eliminate unexpected repair bills and ensure timely filter changes without you having to track service dates.
-
Scheduled Preventive Maintenance Visits: Automatic doorstep service visits every 3 to 4 months for cleaning, sanitization, pressure checks, and TDS calibration.
-
Unlimited Breakdown Support: Priority technician visits at zero extra visiting charges if your RO system develops any issue between scheduled services.
-
Flexible Tiered Coverage Options:
-
Basic Labor AMC (Starts at ₹1,200/year): Covers all scheduled maintenance visits, tank sanitization, TDS tuning, and unlimited breakdown labor charges for one full year; spare parts are billed at discounted rates only when needed.
-
Comprehensive AMC Plans (Model-Dependent): Includes all scheduled labor visits plus scheduled replacement of consumables (spun filter, sediment filter, pre/post carbon filters, and RO membrane/electricals depending on the selected tier).
-
-
Service History & Filter Lifecycle Tracking: Digital tracking of every part installed in your unit so replacements happen strictly on schedule before water quality degrades.
Â
Benefits of Choosing an AMC:
-
Provides a structured maintenance schedule.
-
Helps reduce the possibility of unexpected breakdowns.
-
Supports periodic inspection of important components.
-
Helps identify worn-out filters and developing technical issues.
-
Reduces the inconvenience of arranging individual routine service visits.
-
Helps customers plan maintenance requirements in advance.
-
Supports better monitoring of the system's overall condition.
-
Offers a convenient maintenance arrangement for households and commercial establishments.
Annual Maintenance Contract (AMC) — Starting from ₹1,200/Year
Multibrand RO Services & Repair – Professional Repair, Maintenance & Technical Support
Every RO system relies on its own internal plumbing layout, pressure regulation, cartridge design, and electronic control logic. At Universal Aqua, our technicians inspect out-of-warranty and non-AMC units at the component level—identifying the exact root cause rather than relying on guesswork—and service all major domestic and commercial RO brands with precision-matched spares.
Eureka Forbes Aquaguard RO systems require regular servicing to maintain consistent water output, filtration performance, storage capacity and electrical operation. Professional Aquaguard RO service involves inspecting the complete filtration assembly, checking the membrane, testing the pump, cleaning the storage tank and identifying damaged or exhausted components.
Common Technical Problems & Indicators:
-
Blinking Red or Amber LED Indicator: Triggers when the internal cartridge timer reaches its usage limit or when the UV chamber fails to detect lamp ignition.
-
Water Supply Cut-Off Despite Power On: Often caused by a jammed Solenoid Valve (SV) or a tripped Low-Pressure Switch (LPS) due to erratic overhead tank pressure.
-
Drop in Taste Quality or High Output TDS: Indicates that the i-Filter, Chemi-Block, or Active Copper/Mineral cartridge has reached saturation, or the RO membrane has scaled up from hard borewell water.
Â
A. Aquaguard RO Filter and Cartridge Replacement
-
What is required: Inspection and replacement of the sediment filter, i-Filter, Chemi-Block or carbon cartridge, UF cartridge and post-carbon cartridge, depending on the particular Aquaguard model.
-
When is it needed: When the recommended filter life is reached, the filter becomes clogged, water output decreases, or the machine indicates a filter-life warning.
-
Why is it needed: Blocked or exhausted cartridges can restrict water flow, reduce filtration performance and affect the taste and smell of the output.
-
Warning indicators: Slow tank filling, reduced water production, unpleasant taste, unusual odour, filter alarm or frequent service notifications.
-
Spare parts required: Original-model-compatible i-Filter, sediment cartridge, Chemi-Block, activated carbon filter, UF cartridge and post-carbon cartridge.
B. Aquaguard RO Membrane Replacement
-
What is required: Inspection of the RO membrane and replacement when its dissolved-solids reduction performance or water production capacity deteriorates.
-
When is it needed: When the output TDS is consistently higher than expected, the membrane is clogged, or the membrane no longer produces the required water quantity.
-
Why is it needed: The membrane is responsible for separating dissolved salts and other impurities from incoming water. A deteriorated membrane can affect output quality and production.
-
Warning indicators: Increased output TDS, slow water production, excessive reject water, repeated membrane-related complaints and poor performance even after pre-filter replacement.
-
Spare parts required: Compatible RO membrane, membrane housing O-rings, connectors and membrane housing seals if damaged.
C. Aquaguard Booster Pump and Motor Repair
-
What is required: Checking the booster pump, motor pressure, electrical connections and water pressure.
-
When is it needed: When the unit runs without producing sufficient water, makes unusual noise or fails to start.
-
Why is it needed: The booster pump creates the pressure required for the RO membrane to operate properly.
-
Warning indicators: Continuous motor running, humming noise, low output, irregular water production or failure to fill the storage tank.
-
Spare parts required: Compatible booster pump, pump head, diaphragm assembly, pump connectors or motor-related components, depending on the fault.
D. Aquaguard UV Lamp and UV Chamber Service
-
What is required: Checking the UV lamp, electrical supply, UV chamber and associated connections in models equipped with UV technology.
-
When is it needed: When the UV lamp reaches its rated operating life, a UV error appears or the lamp stops functioning.
-
Why is it needed: The UV assembly provides the model's designed ultraviolet disinfection stage.
-
Warning indicators: UV warning light, UV error notification, continuous beeping or automatic shutdown in models with safety interlocks.
-
Spare parts required: Compatible UV lamp, UV chamber seals, lamp holder, ballast or UV control assembly if defective.
E. Aquaguard SMPS, PCB and Electrical Repair
-
What is required: Diagnosis of the power supply, PCB, wiring, sensors and automatic control system.
-
When is it needed: When the machine does not switch on, indicators malfunction or the system repeatedly stops.
-
Why is it needed: Electrical components control the pump, solenoid valve, UV assembly and automatic operation.
-
Warning indicators: No power indication, flashing error lights, intermittent operation, abnormal switching or pump failure despite a working water supply.
-
Spare parts required: Compatible SMPS, PCB, wiring harness, high-pressure switch, low-pressure switch and electrical connectors.
F. Aquaguard Storage Tank, Leakage and Automatic Shut-Off Repair
-
What is required: Inspection of the storage tank, float mechanism, automatic shut-off system, tubing, tap and connectors.
-
When is it needed: When the tank overflows, the machine continues running after the tank is full or water leaks from the unit.
-
Why is it needed: Faulty shut-off components can cause unnecessary operation, water wastage and leakage.
-
Warning indicators: Continuous water flow, tank overflow, dripping connections, water accumulation beneath the unit or failure to stop automatically.
-
Spare parts required: Float sensor, solenoid valve, check valve, automatic shut-off valve, RO tap, tubing, elbows, connectors and O-rings.
Â
Aquaguard RO service recommendation: Schedule a complete inspection approximately every 6 months as a general maintenance guideline. Some Aquaguard models specify cartridge replacement around 6,000 litres, with UV lamp life depending on its rated operating hours. Always follow the particular model's service manual.
Eureka Forbes Aquaguard RO Services & Repair
Common Technical Problems & Indicators:
-
Excessive Wastewater Reject & Slow Tank Fill: Typically indicates a choked Flow Restrictor (FR) or a heavily scaled RO membrane caused by high-TDS feed water.
-
Loud Humming or Vibrating Cabinet: Occurs when the booster pump works against a clogged sediment filter or when pump head bearings wear down after prolonged use.
-
Continuous Running Without Auto Shut-Off: Signals a stuck magnetic float switch inside the storage tank or a malfunctioning High-Pressure Switch (HPS), risking tank overflow.
-
Filter Change Alarm Buzzer: Kent digital models sound an audible alert once the 60-hour UV/pump operation cycle completes.
​
KENT RO systems use a combination of filtration cartridges, RO membranes, pumps, electrical controls and, depending on the model, UV, UF and TDS control assemblies. KENT RO repair requires model-specific diagnosis because different KENT models use different filter configurations and spare parts.
​
A. KENT RO Sediment and Activated Carbon Filter Replacement
-
What is required: Replacement of the sediment filter and activated carbon filter after checking their condition and service life.
-
When is it needed: When the filters become clogged, their rated capacity is reached or water flow decreases.
-
Why is it needed: The sediment filter removes suspended particles, while the activated carbon stage helps reduce chlorine, organic impurities and unwanted odour.
-
Warning indicators: Slow water flow, frequent filter choking, bad taste, unpleasant smell and reduced tank filling.
-
Spare parts required: KENT-compatible inline sediment filter, activated carbon filter, pre-filter cartridge and filter connectors.
B. KENT RO Membrane Service and Replacement
-
What is required: Testing the membrane's performance by checking incoming and outgoing water TDS, production rate and reject-water flow.
-
When is it needed: When membrane performance decreases, the membrane becomes clogged or output TDS increases beyond the expected operating range.
-
Why is it needed: The RO membrane is essential for reducing dissolved salts and maintaining the designed filtration performance.
-
Warning indicators: Higher output TDS, slow tank filling, continuous operation and poor performance after replacing the pre-filters.
-
Spare parts required: KENT-compatible RO membrane, membrane housing, membrane seals and O-rings.
C. KENT RO Pump and Diaphragm Repair
-
What is required: Inspection of the booster pump, diaphragm, pressure output and motor operation.
-
When is it needed: When the machine runs continuously, produces insufficient water or fails to generate the required pressure.
-
Why is it needed: The pump maintains the pressure required for the RO membrane and proper system operation.
-
Warning indicators: Motor humming, unusual vibration, low water output, frequent starting and stopping, or no water production.
-
Spare parts required: KENT-compatible booster pump, diaphragm pump assembly, pump head, pressure connectors and pump wiring.
D. KENT UF Membrane and UV Assembly Repair
-
What is required: Checking the UF membrane and UV assembly according to the filtration configuration of the installed model.
-
When is it needed: When the UF membrane is clogged or the UV lamp, ballast or associated electrical component stops working.
-
Why is it needed: UF and UV stages provide additional treatment functions in models equipped with these technologies.
-
Warning indicators: UV failure indications, reduced flow, abnormal warning lights or malfunctioning UV operation.
-
Spare parts required: Hollow-fibre UF membrane, UV lamp, UV assembly, UV chamber seals and ballast where applicable.
E. KENT TDS Controller and Flow Restrictor Repair
-
What is required: Inspection of the TDS control valve, flow restrictor and associated water connections.
-
When is it needed: When output TDS becomes inconsistent, reject-water flow is abnormal or membrane operation is affected.
-
Why is it needed: The TDS control mechanism regulates the blending arrangement in applicable models, while the flow restrictor helps maintain the designed membrane operating conditions.
-
Warning indicators: Unusual TDS readings, excessive reject water, inconsistent water production and irregular membrane performance.
-
Spare parts required: Compatible TDS control valve, flow restrictor, check valve, connectors and associated tubing.
F. KENT SMPS, PCB and Sensor Repair
-
What is required: Checking the SMPS, PCB, water-level sensor, low-pressure switch and high-pressure switch.
-
When is it needed: When the unit does not start, stops unexpectedly or fails to detect tank-full conditions.
-
Why is it needed: These components regulate electrical supply, pressure monitoring and automatic water production.
-
Warning indicators: No power, repeated pump activation, failure to stop when full, sensor error and abnormal indicator behaviour.
-
Spare parts required: KENT-compatible SMPS, PCB, float sensor, pressure switches, solenoid valve and wiring connectors.
G. KENT RO Tank, Tap and Leakage Repair
-
What is required: Inspection of the storage tank, water tap, inlet and outlet pipes, and all connecting joints.
-
When is it needed: When water leaks, the tank does not fill properly or the tap becomes difficult to operate.
-
Why is it needed: Damaged connections and faulty tank components can lead to water wastage and reduced convenience.
-
Warning indicators: Continuous dripping, loose tap, tank overflow, low storage capacity or water leakage around the machine.
-
Spare parts required: KENT-compatible storage tank, RO faucet, tank valve, tubing, elbow connectors, non-return valve and O-rings.
Â
KENT RO service recommendation: Arrange periodic inspection based on water consumption and incoming water quality. KENT documentation identifies sediment, carbon, RO membrane, UF membrane and post-carbon components as model-dependent replacement items.
KENT RO Services & Repair
Common Technical Problems & Indicators:
-
Touch Panel Unresponsive or Error Flashing: Often triggered by moisture ingress near the front PCB display or voltage fluctuations damaging the SMPS adapter.
-
Zero Output Water with Pump Running: Commonly caused by air-lock inside the inline filter stages, a choked anti-scalant cartridge, or a blocked post-carbon block.
-
Minor Dripping from Bottom Cabinet: Usually stems from loosened push-fit elbow connectors or hardened rubber O-rings inside the membrane housing.
​
Livpure RO systems require regular maintenance of their filtration cartridges, RO membrane, booster pump, electrical control unit and water storage assembly. Livpure RO service and repair should be performed according to the installed model because different Livpure series may use different filter kits, membrane specifications and electronic monitoring systems.
A. Livpure RO Filter Kit and Cartridge Replacement
-
What is required: Inspection and replacement of the sediment filter, pre-carbon filter, carbon block, post-carbon filter and other inline cartridges fitted in the particular Livpure model.
-
When is it needed: When the filters reach their recommended service life, become clogged or show reduced filtration performance.
-
Why is it needed: The sediment cartridge captures suspended particles, while carbon cartridges help reduce chlorine, unwanted odour and taste-related impurities.
-
Warning indicators: Reduced water flow, slow tank filling, unpleasant taste, unusual smell, filter replacement notification and frequent filter-related errors.
-
Spare parts required: Livpure-compatible sediment filter, pre-carbon cartridge, activated carbon block, post-carbon cartridge, inline filter set and compatible filter housing seals.
B. Livpure RO Membrane Replacement and Performance Testing
-
What is required: Checking membrane efficiency through input and output TDS measurements, water production rate and reject-water flow.
-
When is it needed: When the membrane becomes clogged, its filtration capacity decreases or output TDS rises beyond the expected model-specific range.
-
Why is it needed: The membrane performs the RO separation process and helps reduce dissolved salts and other impurities.
-
Warning indicators: Higher output TDS, low water production, continuous pump operation, excessive reject water and poor output despite fresh pre-filters.
-
Spare parts required: Compatible Livpure RO membrane, membrane housing seals, O-rings and membrane connectors.
C. Livpure Booster Pump and Motor Repair
-
What is required: Inspection of pump pressure, motor performance, diaphragm assembly and electrical connections.
-
When is it needed: When the unit does not produce sufficient water, the motor makes unusual sounds or the pump repeatedly switches on and off.
-
Why is it needed: Proper pump pressure is necessary for the membrane to function at its designed operating capacity.
-
Warning indicators: Humming sound, abnormal vibration, low water output, continuous motor operation and failure to fill the storage tank.
-
Spare parts required: Livpure-compatible booster pump, pump head, diaphragm assembly, pump motor and pressure connectors.
D. Livpure UV Lamp and Electrical Assembly Repair
-
What is required: Testing the UV lamp, ballast, wiring, electrical connections and associated control components in UV-equipped models.
-
When is it needed: When the UV lamp reaches its rated operating life or the system displays a UV-related error.
-
Why is it needed: The UV assembly provides the model's specified ultraviolet disinfection function.
-
Warning indicators: UV indicator failure, warning notifications, abnormal beeping, UV lamp not illuminating or automatic shutdown.
-
Spare parts required: Compatible UV lamp, electronic ballast, UV chamber seals, lamp holder and wiring assembly.
E. Livpure PCB, SMPS and Digital Display Repair
-
What is required: Diagnosis of the main circuit board, power supply, display panel, sensor connections and electronic control system.
-
When is it needed: When the machine fails to start, displays error codes or operates intermittently.
-
Why is it needed: The electronic control unit regulates the motor, filtration cycle, automatic shut-off and monitoring functions in applicable models.
-
Warning indicators: Display not working, flashing indicators, repeated error messages, unexpected shutdown and pump not responding.
-
Spare parts required: Livpure-compatible PCB, SMPS, display board, sensor assembly, wiring harness and electrical connectors.
F. Livpure Automatic Shut-Off and Solenoid Valve Repair
-
What is required: Checking the solenoid valve, automatic shut-off mechanism, water-level sensor and pressure switches.
-
When is it needed: When the machine continues operating after the tank is full or water supply does not stop correctly.
-
Why is it needed: These components control the water inlet, pressure and automatic stopping mechanism.
-
Warning indicators: Continuous motor operation, tank overflow, water wastage, repeated starting and stopping, or failure to refill.
-
Spare parts required: Solenoid valve, high-pressure switch, low-pressure switch, float sensor, non-return valve and automatic shut-off components.
G. Livpure Storage Tank, Tap and Water Leakage Repair
-
What is required: Inspection of the storage tank, outlet tap, tubing, joints and tank valve.
-
When is it needed: When the tank leaks, the tap drips or stored water does not remain at the expected level.
-
Why is it needed: Damaged storage and connecting components can cause leakage, water wastage and reduced storage performance.
-
Warning indicators: Water accumulation below the unit, loose tap, continuous dripping, damaged pipe connections and reduced tank capacity.
-
Spare parts required: Compatible storage tank, Livpure tap, tank valve, food-grade tubing, elbow connectors, O-rings and pipe fittings.
H. Livpure Complete Preventive Maintenance
-
Check all filter stages for choking and leakage.
-
Inspect the RO membrane and measure TDS.
-
Check the pump pressure and motor noise.
-
Inspect UV functionality where applicable.
-
Clean and sanitise the storage tank according to the model's maintenance instructions.
-
Test the automatic shut-off system and water-level sensor.
-
Inspect the SMPS, wiring and PCB for malfunction.
-
Test the complete system after servicing.
Â
Livpure RO service recommendation: A periodic inspection every 6 months is a useful general guideline. Cartridge and membrane replacement should be based on the Livpure model's recommended capacity, water quality, usage and actual performance.
Livpure RO Services & Repair
-
Common Technical Problems & Indicators:
-
Advance Alert System Warning & Auto Water Lock: Pureit models feature a built-in safety shut-off mechanism that stops water flow completely once the Germkill Kit reaches its calibrated liter capacity.
-
Reduced Recovery Rate / Frequent Tank Emptying: Indicates saturation of the Micro-Filtration (MF) membrane or fouling of the high-recovery RO membrane.
-
Metallic or Bitter Aftertaste: Occurs when the post-RO carbon polisher or copper-dosing module is exhausted.
-
​
Pureit RO systems have model-specific filtration assemblies and electronic monitoring features. Certain Pureit models use Germkill Kit cartridges, while other models have separate RO membrane, carbon filtration, UV or additional treatment stages. Professional Pureit RO service involves identifying the exact model and replacing only the compatible components.
A. Pureit Germkill Kit Replacement
-
What is required: Inspection and replacement of the Germkill Kit or model-specific filter assembly.
-
When is it needed: When the kit reaches its recommended usage capacity, the replacement indicator appears or the filtration assembly becomes exhausted.
-
Why is it needed: The Germkill Kit is designed to provide the treatment stages specified for compatible Pureit models. Its performance can decrease after the recommended usage period.
-
Warning indicators: Germkill Kit replacement alert, reduced output, unusual taste, poor filtration performance and system shutdown in models with automatic locking.
-
Spare parts required: Original-model-compatible Germkill Kit, relevant cartridge assembly, connecting seals and locking components.
B. Pureit RO Membrane Replacement
-
What is required: Checking the RO membrane for clogging, reduced output and inadequate dissolved-solids reduction.
-
When is it needed: When the membrane reaches the end of its useful service life or fails performance testing.
-
Why is it needed: The membrane is responsible for reducing dissolved salts and other impurities through the reverse osmosis process.
-
Warning indicators: High output TDS, slow water production, frequent filtration cycles, excessive reject water and poor performance after cartridge replacement.
-
Spare parts required: Pureit-compatible RO membrane, membrane housing, O-rings, seals and connecting fittings.
C. Pureit Sediment and Carbon Filter Service
-
What is required: Checking the sediment and activated carbon stages for blockage and reduced filtration performance.
-
When is it needed: When the cartridges become clogged or reach their recommended replacement capacity.
-
Why is it needed: The sediment stage helps remove suspended particles, while carbon filtration helps reduce chlorine, odour and unwanted taste.
-
Warning indicators: Slow output, discoloured filter cartridges, unpleasant smell, bad taste and reduced water production.
-
Spare parts required: Compatible sediment filter, activated carbon cartridge, carbon block, pre-filter assembly and post-carbon cartridge, depending on the model.
D. Pureit UV Lamp and UV Chamber Repair
-
What is required: Inspection of the UV lamp, ballast, chamber and electrical connections in applicable RO+UV models.
-
When is it needed: When the UV lamp stops functioning, reaches its rated operating life or a UV error appears.
-
Why is it needed: The UV stage provides the additional ultraviolet disinfection function incorporated into the particular model.
-
Warning indicators: UV warning light, repeated error notification, abnormal beeping and failure of the UV assembly.
-
Spare parts required: Compatible UV lamp, electronic ballast, UV chamber assembly, seals and lamp holder.
E. Pureit Pump and Motor Repair
-
What is required: Checking booster pump pressure, motor condition, electrical supply and pump connections.
-
When is it needed: When the system produces less water, makes unusual noise or fails to complete its operating cycle.
-
Why is it needed: The pump provides the pressure needed for the RO membrane to function.
-
Warning indicators: Continuous humming, reduced output, repeated pump activation, low pressure and slow tank filling.
-
Spare parts required: Compatible RO booster pump, motor, pump head, diaphragm and electrical connectors.
F. Pureit Digital Display, Alert System and PCB Repair
-
What is required: Testing the display board, PCB, filter-life monitoring system, wiring and electronic sensors.
-
When is it needed: When filter indicators malfunction, the display becomes unresponsive or the machine displays repeated errors.
-
Why is it needed: The electronic system monitors filtration stages, replacement alerts and operating functions in equipped models.
-
Warning indicators: Blinking lights, continuous beeping, replacement warnings after servicing, blank display and unexpected system shutdown.
-
Spare parts required: Compatible PCB, display board, SMPS, sensor assembly, indicator panel and wiring harness.
G. Pureit Solenoid Valve and Automatic Shut-Off Repair
-
What is required: Inspection of the water inlet valve, automatic shut-off assembly, pressure switches and tank-level sensors.
-
When is it needed: When water continues entering the system after the tank is full or the machine fails to start its operating cycle.
-
Why is it needed: These components regulate water flow and automatic operation.
-
Warning indicators: Tank overflow, continuous water flow, irregular pump operation, no water entering the system and repeated switching.
-
Spare parts required: Solenoid valve, float sensor, high-pressure switch, low-pressure switch, check valve and water inlet connectors.
H. Pureit Storage Tank and Tap Repair
-
What is required: Checking the tank, outlet tap, tubing and storage connections.
-
When is it needed: When water leaks, the tap becomes loose or the tank fails to maintain its normal storage level.
-
Why is it needed: Proper storage and leak-free connections are necessary for convenient and hygienic operation.
-
Warning indicators: Dripping tap, water below the unit, tank leakage, reduced storage capacity and damaged pipe joints.
-
Spare parts required: Compatible Pureit storage tank, tap, tank valve, tubing, O-rings and connectors.
Â
Pureit RO service recommendation: Check the Germkill Kit replacement indicator and follow the particular model's recommended cartridge life. Do not replace a Germkill Kit with a generic filter set unless the manufacturer specifies compatibility.
Pureit RO Services & Repair
Common Technical Problems & Indicators:
-
Water Leakage from Filter Bowls or Membrane Cap: Commonly caused by cracked 10-inch pre-filter housings due to high municipal line pressure or worn-out housing O-rings.
-
Sudden Spike in Output TDS: Often occurs when the manual TDS adjuster needle shifts or when a standard 75/80 GPD membrane ruptures under unbuffered pump pressure.
-
Foul Odor from Stored Water: Happens when the inline post-carbon or alkaline cartridge is overdue for replacement or the storage tank lacks periodic sanitization.
​
Aquafresh RO systems are available in different configurations, including domestic RO, RO+UV, RO+UF and mineral-enhanced models. Aquafresh RO service requires inspection of the filtration stages, membrane, pump, electrical components, storage tank and water connections.
Â
A. Aquafresh Sediment Filter and Pre-Filter Replacement
-
What is required: Inspection and replacement of the external pre-filter, sediment cartridge and spun filter candle.
-
When is it needed: When the filter becomes clogged, water flow decreases or accumulated dirt affects filtration.
-
Why is it needed: The pre-filter protects the internal filtration assembly from suspended particles, dust, sand and other sediments.
-
Warning indicators: Reduced inlet flow, dirty filter cartridge, frequent membrane choking and slow tank filling.
-
Spare parts required: Aquafresh-compatible spun filter candle, sediment cartridge, pre-filter housing, housing cap and O-rings.
B. Aquafresh Carbon Filter Replacement
-
What is required: Checking and replacing the pre-carbon and post-carbon cartridges.
-
When is it needed: When the carbon cartridge reaches its recommended service life or taste and odour problems develop.
-
Why is it needed: Carbon filtration helps reduce chlorine, organic impurities and unwanted taste and smell.
-
Warning indicators: Unpleasant water taste, unusual smell, reduced filtration performance and exhausted carbon cartridges.
-
Spare parts required: Activated carbon filter, CTO carbon block, GAC cartridge, post-carbon filter and compatible connectors.
C. Aquafresh RO Membrane Replacement
-
What is required: Testing the membrane's performance through TDS measurement, output quantity and reject-water inspection.
-
When is it needed: When the membrane becomes clogged, damaged or unable to maintain the expected output quality.
-
Why is it needed: The membrane reduces dissolved salts and other impurities from incoming water.
-
Warning indicators: High output TDS, reduced water production, slow tank filling, excessive reject water and recurring membrane-related problems.
-
Spare parts required: Compatible 75 GPD, 80 GPD or 100 GPD membrane, depending on the system specification, along with membrane seals and connectors.
D. Aquafresh RO Booster Pump Repair
-
What is required: Checking the pump, motor, diaphragm and pressure output.
-
When is it needed: When the motor runs continuously, the system produces insufficient water or pump pressure becomes unstable.
-
Why is it needed: The booster pump supplies the pressure required for membrane filtration.
-
Warning indicators: Motor noise, vibration, low water output, pump overheating and repeated starting.
-
Spare parts required: RO booster pump, 75/100 GPD compatible pump assembly, diaphragm, pump head, motor and electrical connectors.
E. Aquafresh UV and UF Assembly Service
-
What is required: Inspection of UV lamps, UV chambers and UF membranes in models equipped with these stages.
-
When is it needed: When the UV lamp reaches its rated life, the UF membrane becomes clogged or the assembly stops functioning.
-
Why is it needed: UV provides an additional disinfection stage, while UF offers additional filtration through its membrane.
-
Warning indicators: UV light failure, low water flow, abnormal indicators and recurring UV-related errors.
-
Spare parts required: UV lamp, ballast, UV chamber, UF membrane, connecting seals and electrical wiring.
F. Aquafresh SMPS, PCB and Automatic System Repair
-
What is required: Inspection of the electrical supply, PCB, automatic shut-off system and pressure sensors.
-
When is it needed: When the unit fails to start, stops unexpectedly or does not operate automatically.
-
Why is it needed: These components control electrical supply, motor operation and water flow.
-
Warning indicators: No power, flashing lights, continuous pump operation and failure to stop when the tank is full.
-
Spare parts required: SMPS, PCB, solenoid valve, low-pressure switch, high-pressure switch and float sensor.
G. Aquafresh Leakage and Storage Tank Repair
-
What is required: Inspection of storage tank connections, water pipes, taps and filter housings.
-
When is it needed: When water leaks from the housing, tap or connecting pipes.
-
Why is it needed: Damaged joints and seals can lead to continuous water leakage and reduced storage capacity.
-
Warning indicators: Water dripping, loose connections, cracked filter housing, damaged tap and water accumulation beneath the machine.
-
Spare parts required: Storage tank, RO tap, filter housing, pipe connectors, food-grade tubing, elbows, O-rings and valves.
H. Aquafresh Complete Servicing and Maintenance
-
Inspect all filtration cartridges.
-
Check membrane performance and TDS levels.
-
Clean the filter housing and storage tank.
-
Inspect the booster pump and electrical connections.
-
Check the reject-water line.
-
Examine all pipe connections for leakage.
-
Test automatic shut-off functionality.
-
Check output water flow after servicing.
Â
Aquafresh RO service recommendation:Â A six-month inspection is a useful general maintenance guideline. Filter and membrane replacement should depend on input-water conditions, consumption and actual component performance.
Aquafresh RO Services & Repair
-
Aquagrand RO systems require proper maintenance of their filter cartridges, membrane, booster pump, storage tank and electrical components. Different Aquagrand models may have different filtration stages, so the technician should identify the model before recommending spare parts.
-
A. Aquagrand RO Filter Replacement
-
What is required: Inspection and replacement of sediment, pre-carbon, carbon block and post-carbon filters.
-
When is it needed: When filters become clogged, reach their recommended replacement capacity or cause reduced water flow.
-
Why is it needed: Filters help remove suspended particles, chlorine and unwanted taste-related impurities before and after the membrane stage.
-
Warning indicators: Slow water flow, bad taste, unpleasant smell, dirty filter cartridges and reduced storage-tank filling.
-
Spare parts required: Aquagrand-compatible sediment filter, spun filter, carbon cartridge, pre-carbon filter, post-carbon filter and filter housing seals.
-
B. Aquagrand RO Membrane Service
-
What is required: Checking membrane performance through TDS testing, water output measurement and membrane pressure inspection.
-
When is it needed: When the membrane becomes clogged or its dissolved-solids reduction performance deteriorates.
-
Why is it needed: The RO membrane is the main stage for reducing dissolved salts and other impurities.
-
Warning indicators: High output TDS, slow water production, continuous pump operation and increased reject-water flow.
-
Spare parts required: Compatible RO membrane, membrane housing, membrane O-rings, connectors and seals.
-
C. Aquagrand RO Pump and Motor Repair
-
What is required: Testing the pump's pressure, motor performance and electrical supply.
-
When is it needed: When the motor runs without sufficient output or stops working completely.
-
Why is it needed: The pump creates the required operating pressure for the membrane.
-
Warning indicators: Humming sound, motor vibration, low water production, overheating and irregular pump operation.
-
Spare parts required: Booster pump, pump head, diaphragm, motor and compatible pressure connectors.
-
D. Aquagrand UV and UF Repair
-
What is required: Inspection of UV and UF stages, where installed.
-
When is it needed: When the UV lamp stops working or the UF cartridge becomes clogged.
-
Why is it needed: These stages provide the additional treatment functions specified in the model.
-
Warning indicators: UV failure, reduced output flow, warning lights and unusual system operation.
-
Spare parts required: UV lamp, ballast, UV chamber, UF membrane and connecting seals.
-
E. Aquagrand SMPS and PCB Repair
-
What is required: Testing the electrical supply, circuit board and wiring.
-
When is it needed: When the machine does not start or repeatedly stops.
-
Why is it needed: The electrical system controls pump operation and automatic functions.
-
Warning indicators: No power, blinking lights, unexpected shutdown and motor failure.
-
Spare parts required: SMPS, PCB, wiring harness, electrical connectors and compatible sensors.
-
F. Aquagrand Solenoid Valve and Leakage Repair
-
What is required: Checking the inlet valve, automatic shut-off mechanism and connecting pipes.
-
When is it needed: When the machine fails to stop water flow or develops leakage.
-
Why is it needed: The valve and automatic controls regulate the water supply.
-
Warning indicators: Continuous water flow, tank overflow, dripping connections and repeated pump activation.
-
Spare parts required: Solenoid valve, check valve, float sensor, tubing, connectors and O-rings.
-
G. Aquagrand Storage Tank and Tap Replacement
-
What is required: Checking the storage tank, outlet tap and tank connections.
-
When is it needed: When the tank leaks, the tap becomes damaged or storage capacity decreases.
-
Why is it needed: Proper storage and leak-free dispensing are essential for normal daily use.
-
Warning indicators: Tank leakage, dripping tap, loose joints and water accumulation below the unit.
-
Spare parts required: Compatible storage tank, RO tap, tank valve, food-grade pipes and connectors.
Aquagrand RO Services & Repair
Frequently Asked Questions: RO Repair, Service & Troubleshooting
Q: Why is my RO system dispensing water very slowly or taking hours to fill the tank? A: Slow water output usually happens when the pre-filter, sediment cartridge, or RO membrane is choked with accumulated silt and mineral scale. It can also occur if the booster pump has lost pressure and can no longer push water through the membrane at the required PSI.
Q: Why does wastewater keep flowing out of the drain pipe even when the tank is full? A: Continuous drainage when the unit is idle indicates a faulty Solenoid Valve (SV) or Auto Shut-Off Valve (ASOV). When these valves fail to close tightly, raw inlet water bypasses the shut-off mechanism and flows straight into the drain line, wasting water and increasing utility bills.
Q: Why is my RO system vibrating loudly or making a grinding noise? A: Excessive noise or vibration typically points to a worn-out booster pump head, air trapped inside the filter housings after a water supply interruption, or a severely clogged sediment filter forcing the pump to strain against restricted water flow.
Q: Why does my RO water taste bitter, metallic, or unusual? A: A sudden change in taste or odor means the activated carbon filter or post-carbon/mineral cartridge has reached saturation and can no longer absorb chlorine and organic compounds. It can also indicate that the RO membrane has degraded, allowing high-TDS dissolved salts into the storage tank.
Q: Why does my RO unit not turn on, or why are indicator lights blinking? A: If the unit is completely dead, the SMPS power adapter may have failed due to voltage fluctuations, or the Low-Pressure Switch (LPS) may have cut power because overhead tank water pressure is too low. Blinking red or amber lights typically signal an expired filter timer or a faulty UV lamp ballast.
Q: Why does the motor keep running continuously without shutting off automatically? A: When the storage tank fills up, a float switch or High-Pressure Switch (HPS) is supposed to cut power to the pump and solenoid valve. If either switch is stuck or faulty, the motor continues running nonstop, risking pump overheating and water overflow.
Q: What does an alarm beep or blinking light indicator mean? A: Modern RO systems use electronic circuit boards to trigger alarms for specific maintenance events: Filter Life Limit: Scheduled cartridge lifespan has expired. UV Fault: The ultraviolet tube or electronic UV choke has failed. Leak Sensor: Internal sensors detected water in the base tray. Action: Check the specific indicator code in your user manual or request a control board diagnostic reset.
Q: Why is reject water flowing continuously even when the unit is turned off? A: Continuous drain flow occurs when the solenoid valve (SV) fails mechanically in an open position or when raw water supply pressure bypasses an unpowered valve. Replacing the faulty solenoid valve stops ongoing water wastage.
Q: What is a Pre-Filter Candle and when should it be replaced? A: The pre-filter is a 5-micron spun polypropylene cartridge housed in an external bowl outside the cabinet. It traps coarse sand, mud, silt, and rust. It must be replaced every 3 to 6 months to prevent heavy abrasives from entering and damaging internal pump seals.
Q: How often does the RO Membrane need replacement? A: The semi-permeable membrane (0.0001 micron) typically lasts 12 to 24 months. Lifespan depends heavily on incoming water TDS levels and how consistently pre-filters are changed. High purified water TDS or severely reduced water flow indicates membrane failure.
Q: What does a High-Pressure Booster Pump do? A: The booster pump generates the hydraulic pressure (60 to 80 PSI) required to force water molecules through the sub-microscopic pores of the semi-permeable membrane. Low pump pressure reduces pure water recovery and increases reject water volume.